HASS

Amber Press MO

Price
$140.00
Shade:

HASS · LITHIUM DISILICATE PRESS INGOT

Strong Foundation.
Layered Esthetics.

Amber Press is a lithium disilicate press ingot developed for stable pressing, high esthetics and efficient laboratory processing. Its crystallised cross-linked microstructure supports thin margins, reduced chipping and minimal reaction layer after pressing. The MO range is designed for frameworks and restorations where increased masking and a layered ceramic workflow are required.

460 MPa Biaxial Strength Minimal Reaction Layer No Acid Clean-Up Required Thin Margin Stability MO · Layering Workflow
460 MPaBiaxial Flexural Strength
LowReaction Layer After Pressing
0Acid Clean-Up Step Required*
MOSelected Optical Family

*HASS states that Amber Press leaves minimal reaction layer and does not require acid liquid for clean-up when processed according to the manufacturer's workflow. Always follow the current IFU.

WHY AMBER PRESS

Designed for the Press Lab.

Amber Press combines the familiar lost-wax pressing technique with a lithium disilicate material engineered for strength, edge stability and cleaner post-press processing.

01

Strength + Thin Margins

HASS reports 460 MPa biaxial flexural strength, while the material's microstructure helps support thin restoration margins with reduced chipping.

02

Minimal Reaction Layer

Amber Press is engineered to leave very little reaction layer after pressing, simplifying divesting and post-press clean-up.

03

Natural Esthetics

Multiple translucency and opacity options support staining, cut-back and layering approaches across a broad range of restorative cases.

SELECTED TRANSLUCENCY

MO · Built for Masking and Layering.

MO Medium Opacity

MO is the framework-oriented option in the Amber Press family. Use it when control of the underlying substrate is important and the final esthetics will be developed with veneering ceramic.

Layering-OrientedHASS positions MO for layering workflows rather than primarily stain-only finishing.
Control the SubstrateMedium opacity helps reduce the visual influence of the underlying preparation or framework where additional masking is required.
Build Final EstheticsUse compatible veneering ceramic to develop morphology, depth and optical character over the pressed framework.

INDICATIONS

One Press System. Broad Restorative Coverage.

Amber Press is indicated for a range of lithium disilicate restorations. Follow the current HASS IFU for design, minimum thickness, connector dimensions and case selection.

Veneers
Inlays
Onlays
Anterior Crowns
Posterior Crowns
3-Unit Bridges*

*Manufacturer documentation lists 3-unit bridges with posterior extension limited to the second premolar. Confirm the current IFU before case selection.

PRESS WORKFLOW

From Wax Pattern to Final Ceramic.

Amber Press is designed around the conventional lost-wax pressing technique used in dental laboratories.

01Wax-Up
02Sprue
03Invest
04Burnout
05Press
06Divest
07Layer & Finish

CLEANER POST-PRESS PROCESSING

Less Reaction Layer. Less Clean-Up.

One of Amber Press's strongest laboratory advantages is what happens after pressing.

Minimal Reaction Layer

HASS states that Amber Press leaves only a small amount of reaction layer after pressing, helping simplify post-press processing and reduce unnecessary adjustment.

No Acid Liquid Required

According to HASS, acid liquid is not required for reaction-layer clean-up in the recommended Amber Press workflow, supporting a simpler and less hazardous laboratory process.

VENEERING FLEXIBILITY

Work With Familiar Ceramic Systems.

Amber Press is compatible with a range of veneering materials intended for lithium disilicate restorations. HASS also publishes specific guidance for selected zirconia veneering porcelains when used with Amber Press.

Lithium Disilicate VeneeringStainingCut-BackLayering
Upload Amber Press layering / veneering image in Theme Customize

REAL RESTORATIONS

Press for Strength. Finish for Esthetics.

Use HASS or DDA-approved cases to show the final optical result, margin quality and the difference between monolithic, cut-back and layered techniques.

Upload Amber Press anterior case

Anterior Esthetics

Show natural contour, translucency and surface character in highly visible anterior restorations.

Upload Amber Press layered / cut-back case

Layered Restorations

Highlight the MO framework's ability to support layered ceramic esthetics.

Upload Amber Press posterior case

Posterior Restorations

Show practical laboratory results for inlays, onlays and posterior crowns within the manufacturer's indication and design requirements.

PRESS OR MILL?

Amber Press vs Amber Mill

Both use HASS lithium disilicate technology, but the production workflow is fundamentally different.

FeatureAmber PressAmber Mill
Manufacturing MethodLost-wax press techniqueCAD/CAM milling
Best FitLaboratories using wax-up, investment and ceramic pressing workflowsDigital CAD/CAM laboratories and clinics
Reported Strength460 MPa biaxial flexural strengthApprox. 450 MPa fully crystallised
Optical SelectionDedicated HT, LT and MO ingot familiesHeat-treatment-based translucency control across HT+, HT, MT, LT and MO
Finishing ApproachMO: layering-orientedCrystallisation followed by polish, stain and/or glaze according to the selected protocol
Key Workflow AdvantageMinimal reaction layer and no acid clean-up requirement in the recommended workflowDigital design, milling and adjustable translucency

TECHNICAL INFORMATION

Amber Press MO Specifications

MaterialLithium disilicate-based press ingot
Product FamilyAmber Press
Selected TranslucencyMO · Medium Opacity
Reported Biaxial Flexural Strength460 MPa
Primary TechniqueLayering workflow
Reaction LayerMinimal after pressing according to HASS
Acid Clean-UpNot required in the manufacturer's recommended Amber Press workflow
IndicationsVeneers, inlays, onlays, anterior single crowns, posterior single crowns and manufacturer-specified 3-unit bridges. Always follow the current HASS IFU.
Compatible ProcessingUse appropriate lithium disilicate investment, press furnace settings and HASS pressing schedules for the selected furnace.
Current DDA ShadesMO 0 · MO 1 · MO 2 · MO 3 · MO 4

Manufacturer-reported physical-property and workflow data. Pressing results depend on investment, furnace calibration, pressing parameters, restoration design and finishing procedure. Refer to the current HASS Instructions for Use and pressing schedule for your furnace before clinical use.

FREQUENTLY ASKED QUESTIONS

Amber Press Workflow Questions

What is the difference between Amber Press HT, LT and MO?

HT is the more translucent option, LT provides increased masking, and MO is the more opaque framework-oriented option. HASS positions HT and LT primarily for staining / cut-back workflows and MO for layering.

Does Amber Press require acid reaction-layer removal?

HASS states that Amber Press produces only a small reaction layer and does not require acid liquid for clean-up when processed according to the recommended workflow.

Can Amber Press be layered with veneering ceramic?

Yes. HASS documents compatibility with multiple veneering systems. Always confirm the current HASS guideline and the veneering ceramic manufacturer's instructions before use.

Is Amber Press the same material as Amber Mill?

They are both lithium disilicate-based HASS restorative materials, but Amber Press is processed by the lost-wax press technique, while Amber Mill is a CAD/CAM material designed for milling and subsequent crystallisation.

PRESS CERAMIC SUPPORT FROM DDA

Need Help With Your Lithium Disilicate Press Workflow?

Dental Dynamics Australia supports dental laboratories with pressable ceramics, furnaces, investment materials and practical ceramic workflows. Talk to our team about Amber Press selection, furnace compatibility, pressing schedules and finishing techniques.

Talk to a DDA Expert